Eur Radiol ; 30(5): 2740-2750, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31974689

RESUMO

OBJECTIVES: To evaluate and compare the image quality of propagation-based phase-contrast computed tomography (PB-CT) using synchrotron radiation and conventional cone-beam breast computed tomography (CBBCT) based on various radiological image quality criteria. METHODS: Eight excised breast tissue samples of various sizes and containing different lesion types were scanned using PB-CT at a synchrotron facility and using CBBCT at a university-affiliated breast imaging centre. PB-CT scans were performed at two different mean glandular dose (MGD) levels: standard (5.8 mGy) and low (1.5 mGy), for comparison with CBBCT scans at the standard MGD (5.8 mGy). Image quality assessment was carried out using six quality criteria and six independent medical imaging experts in a reading room with mammography workstations. The interobserver agreement between readers was evaluated using intraclass correlation coefficient (ICC), and image quality was compared between the two breast imaging modalities using the area under the visual grading characteristic curve (AUCVGC). RESULTS: Interobserver agreement between the readers showed moderate reliability for five image criteria (ICC: ranging from 0.488 to 0.633) and low reliability for one criterion (image noise) (ICC 0.307). For five image quality criteria (overall quality, perceptible contrast, lesion sharpness, normal tissue interfaces, and calcification visibility), both standard-dose PB-CT images (AUCVGC 0.958 to 1, p ≤ .05) and low dose PB-CT images (AUCVGC 0.785 to 0.834, p ≤ .05) were of significantly higher image quality than standard-dose CBBCT images. CONCLUSIONS: Synchrotron-based PB-CT can achieve a significantly higher radiological image quality at a substantially lower radiation dose compared with conventional CBBCT. KEY POINTS: • PB-CT using synchrotron radiation results in higher image quality than conventional CBBCT for breast imaging. • PB-CT using synchrotron radiation requires a lower radiation dose than conventional CBBCT for breast imaging. • PB-CT can help clinicians diagnose patients with breast cancer.


Assuntos
Doenças Mamárias/diagnóstico , Mama/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Mamografia/métodos , Síncrotrons , Feminino , Humanos , Doses de Radiação , Reprodutibilidade dos Testes
2.
Acad Radiol ; 26(6): e79-e89, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30149975

RESUMO

RATIONALE AND OBJECTIVES: This study employs clinical/radiological evaluation in establishing the optimum imaging conditions for breast cancer imaging using the X-ray propagation-based phase-contrast tomography. MATERIALS AND METHODS: Two series of experiments were conducted and in total 161 synchrotron-based computed tomography (CT) reconstructions of one breast mastectomy specimen were produced at different imaging conditions. Imaging factors include sample-to-detector distance, X-ray energy, CT reconstruction method, phase retrieval algorithm applied to the CT projection images and maximum intensity projection. Observers including breast radiologists and medical imaging experts compared the quality of the reconstructed images with reference images approximating the conventional (absorption) CT. Various radiological image quality attributes in a visual grading analysis design were used for the radiological assessments. RESULTS: The results show that the application of the longest achievable sample-to-detector distance (9.31 m), the lowest employed X-ray energy (32 keV), the full phase retrieval, and the maximum intensity projection can significantly improve the radiological quality of the image. Several combinations of imaging variables resulted in images with very high-quality scores. CONCLUSION: The results of the present study will support future experimental and clinical attempts to further optimize this innovative approach to breast cancer imaging.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Mamografia/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Mama/diagnóstico por imagem , Feminino , Humanos
3.
J Synchrotron Radiat ; 25(Pt 5): 1460-1466, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30179186

RESUMO

The aim of this study was to highlight the advantages that propagation-based phase-contrast computed tomography (PB-CT) with synchrotron radiation can provide in breast cancer diagnostics. For the first time, a fresh and intact mastectomy sample from a 60 year old patient was scanned on the IMBL beamline at the Australian Synchrotron in PB-CT mode and reconstructed. The clinical picture was described and characterized by an experienced breast radiologist, who underlined the advantages of providing diagnosis on a PB-CT volume rather than conventional two-dimensional modalities. Subsequently, the image quality was assessed by 11 breast radiologists and medical imaging experts using a radiological scoring system. The results indicate that, with the radiation dose delivered to the sample being equal, the accuracy of a diagnosis made on PB-CT images is significantly higher than one using conventional techniques.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Mama/cirurgia , Feminino , Humanos , Técnicas In Vitro , Mastectomia , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído
4.
IEEE Trans Med Imaging ; 37(12): 2642-2650, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29994112

RESUMO

Histopathological analysis is the current gold standard in breast cancer diagnosis and management, however, as imaging technology improves, the amount of potential diagnostic information that may be demonstrable radiologically should also increase. We aimed to evaluate the potential clinical usefulness of 3-D phase-contrast micro-computed tomography (micro-CT) imaging at high spatial resolutions as an adjunct to conventional histological microscopy. Ten breast tissue specimens, 2 mm in diameter, were scanned at the SYRMEP beamline of the Elettra Synchrotron using the propagation-based phase-contrast micro-tomography method. We obtained pixel size images, which were analyzed and compared with corresponding histological sections examined under light microscopy. To evaluate the effect of spatial resolution on breast cancer diagnosis, scans with four different pixel sizes were also performed. Our comparative analysis revealed that high-resolution images can enable, at a near-histological level, detailed architectural assessment of tissue that may permit increased breast cancer diagnostic sensitivity and specificity when compared with current imaging practices. The potential clinical applications of this method are also discussed.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imageamento Tridimensional/métodos , Microtomografia por Raio-X/métodos , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Pessoa de Meia-Idade